Enable the user
ports on S1, S2, and S3 in access mode.
S1#conf t
S1(config)# int fa0/6
S1(config-if)#no shut
S1(config-if)#switchport mode access
S2#conf t
S2(config)# int fa0/18
S2(config-if)#no shut
S2(config-if)#switchport mode access
S3#conf t
S3(config)# int fa0/11
S3(config-if)#no shut
S3(config-if)#switchport mode access
Create VLANs.
S1#conf t
Enter configuration commands, one per line. End with CNTL/Z.
S1(config)#vlan 10
S1(config-vlan)#vlan 20
S1(config-vlan)#vlan 30
S1(config-vlan)#vlan 40
S1(config-vlan)#vlan 50
S1(config-vlan)#vlan 60
S1(config-vlan)#vlan 70
S1(config-vlan)#vlan 80
S1(config-vlan)#vlan 99
Using above command create VLANs for S2 & S3.
Assign VLANs & IP Address to switch ports.
S1(config)#int fa0/6
S1(config-if)#switchport access vlan 30
S1(config)#int vlan 30
S1(config-if)#ip address 172.17.30.1 255.255.255.0
S2(config)#int fa0/18
S2(config-if)#switchport access vlan 20
S2(config)#int vlan 20
S2(config-if)#ip address 172.17.20.1 255.255.255.0
S3(config)#int fa0/11
S3(config-if)#switchport access vlan 10
S3(config)#int vlan 10
S3(config-if)#ip address 172.17.10.1 255.255.255.0
Assign the
trunks to native VLAN 99 for all SWs ports F0/1 to F0/4.
S1(config)#int range fa0/1-4
S1(config-if-range)#switchport mode trunk
S1(config-if-range)#switchport trunk native vlan 99
S1(config-if-range)#exit
S1(config)#int vlan 99
S1(config-if)#ip address 172.31.99.1 255.255.255.0
S2(config)#int range fa0/1-4
S2(config-if-range)#switchport mode trunk
S2(config-if-range)#switchport trunk native vlan 99
S2(config-if-range)#exit
S2(config)#int vlan 99
S2(config-if)#ip address 172.31.99.2 255.255.255.0
S3(config)#int range fa0/1-4
S3(config-if-range)#switchport mode trunk
S3(config-if-range)#switchport trunk native vlan 99
S3(config-if-range)#exit
S3(config)#int vlan 99
S3(config-if)#ip address 172.31.99.3 255.255.255.0
Configure STP
mode.
Configure S1 to be the primary root for VLANs
1, 10, 30, 50, and 70. Configure S3 to be the primary root for VLANs
20, 40, 60, 80, and 99. Configure S2 to be the secondary root for all
VLANs
S1(config)#spanning-tree mode pvst
S1(config)#spanning-tree vlan 1,10,30,50,70 root primary
S3(config)#spanning-tree mode pvst
S3(config)#spanning-tree vlan 20,40,60,80,99 root primary
S3(config)#spanning-tree mode pvst
S2(config)# spanning-tree vlan 1,10,20,30,40,50,60,70,80,99
root secondary
Configure PortFast on the
switches.
S1(config-if)#spanning-tree portfast
Configure BPDU
guard on the switches.

No comments:
Post a Comment